Showing results: 121 - 135 of 393 items found.
-
SFH141 -
Shanghai Launch Electric Co., Ltd.
This instrument is especially designed to test volt-ampere characteristics, transformation ratio and polarity differences for relay protection testing current transformers. It is also used to judge the polarity of transformers, as a multi-functional instrument with excellent cost performance. The instrument takes use of transformer with special winding method, as well as high efficiency, low consume materials.
-
Hilkar
High Current Transformer is designed to elevate and check the temperature of the conductors at high current levels, in order to simulate the current loading conditions found in electrical circuits. High Current Transformer is designed as an open type transformer that uses the test object as its secondary coil or has 1 or 2-turn self secondary winding. The conductors cores' temperature depends on the short-circuit high current caused by the test object. According to the current going through the test object, the test temperature of the conductor will change. The loop temperature is measured by a thermocouple probe which is directly connected to conductor.
-
STDE -
Altanova Group
This option allows neutralizing the residual magnetization of the power transformer core after the winding resistance test. The principle of the option is to apply a constant current of alternate polarities to the transformer winding, as per the IEEE 0062 1995 standard.
-
TRM 1000 -
AJIT Electronics Co.
AJIT Transformer Ratio Meters are the most modern turn's radio meters widely used to test the turn's ratio of high voltage windings, to low voltage windings, of Transformer. These meters are accurate, compact & light in weight.
-
TR-1C -
Criterion Instruments Limited
Model TR-1C Transformer Ratiometer is a precision test set with an easy-to-read in-line digital readout from 0.00001 to 1.00000, suitable for testing all types of single and three-phase power distribution, potential and current transformers.
-
865 -
The Eastern Specialty Company
This instrument is used to check the correctness of polarity markings on transformers. In operation, the two leads carrying the test current are connected to one of the transformer windings. The other two leads from the indicating meter are connected to the other winding.
-
SF-2001 -
Shanghai Launch Electric Co., Ltd.
SF-2001 interference discriminant PD detector is featured by high sensitivity and wide usage. It is mainly used to test partial discharge for transformers, instrument transformers, cables, bushings, capacitors, generators and other high voltage apparatus.
-
T-REX -
Raytech AG
The Raytech three phase voltage system option T-Rex is an optional system accessory for 3-Phase transformer ratio meter test sets designed by Raytech (i.e. TR-MARK III). T-Rex was designed to give Engineers and Test Technicians the ability to test the phase relationships and actual voltage ratios of transformer windings while applying three phase voltage.
-
Kvtester Electronics Technology Co.,Ltd
High precision instrument for measuring characteristic parameters of transformer capacity, no-load and load. The instrument is a multi-function measuring instrument, which is equivalent to the usual two kinds of test instruments: the transformer capacity tester + transformer characteristic parameter tester. The utility model can precisely measure a series of power frequency parameters of a plurality of transformers, such as the capacity, the type, the no-load current, the no-load loss, the short circuit (load) loss and the impedance voltage.
-
HDFZ -III -
HD Power Test Equipment Co.ltd
HDFZ-III Transformer Power Tester is an multi-function instrument which is used to test accurately a serious of parameters such as capacity, type, no-load current ,no-load loss, impedance voltage of various transformers. The test result of capacity and characteristic can be up to 100% accuracy rate. The capacity measurement range :10kVA~100000kVA。
-
Weshine Electric Manufacturing Co., Ltd
1. Full three-phase sinusoidal inverter power output, output voltage is automatically adjusted, with soft start and soft stop functions, so the test speed is fast and the accuracy is high.2. The instrument has single-phase, three-phase, Z-type transformers, voltage transformer ratio, group, polarity test functions.
-
J2120A -
PICOTEST Corp.
While the injection transformer is a very wideband adapter, it is not useful for measuring ripple rejection (PSRR) of a power supply or even an opamp. This is because the attributes that make the injection transformer perform so well also result in a transformer that is intolerant of DC current. Even very small DC currents (5mA or less) can greatly reduce the signal capacity or even totally saturate the transformer. For this reason, the Picotest line injector (J2120A) is another essential test adapter.
-
-
Langer EMV-Technik GmbH